11
2017 Page 169 5IN2413 B
Quick Keys Parameter Default Range
Random MS Testing
No Yes/No
Yes: At power-up the panel randomly set a test time between 00:00
and 23:59. Once the hour is set, this will be the fixed report hour of
this panel. The time can be viewed under the Periodic test timer
fields (). The interval of sending the test will be as defined
under the Periodic Test timer
No: The periodic test will be according to the time defined under the
MS periodic timer (
).
SIA W/Partition
No Yes/No
Indicates the partition when reporting to the monitoring station in
SIA over the voice channel (GSM).
Yes: SIA format report to MS will support text transmission over the
voice channel.
Note
The monitoring station receiver should support the SIA Text protocol
No: SIA format will not support text
Communication Monitoring Station Parameters
Quick Keys Parameter Default Range
Parameters
Programmable parameters related to operation with the MS
MS Retries
08
01—15
The number of times the ProSYS Plus redials the monitoring station
after failing to establish communication.
NOTE: If there is a communication fault with the monitoring station
the panel will not be ready to arm.
Alarm Restore
Specifies under what conditions an Alarm Restoral is reported. This
option informs the MS of a change in the specified condition(s) during
an alarm restore. These reports need a valid Report Code.
ON BTO (Bell Time Out) – Reports the restoral after the audible
alarm times out.
FOLLOW ZONE – Reports the restoral when the zone in which the
alarm occurs returns to its non-violated (secured) state.
AT DISARM – Reports the restoral when system (or the partition
in which the alarm occurs) is disarmed, even if the siren has timed out.