EasyManua.ls Logo

Risco ProSYS Plus - Page 168

Risco ProSYS Plus
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
/
2017 Page 168 5IN2413 B
Communication Monitoring Station Controls
Quick Keys Parameter Default Range

Controls
Programmable controls related to communication between the
system and the monitoring station

Call Save
No
Yes/No
YES: For reducing MS traffic congestion, the system holds all non-
urgent events (for example, opening/closing reports, test
transmissions) for up to 12 hours (programmable) and sends them as
a batch at a less busy time, for example, at night (see
Periodic Test,
page 171).
NO: All events are transmitted as they occur.

Show Kissoff
No
Yes/No
YES: The keypad indicates when the dialer receives the kissoff signal
from the MS’s receiver.
NO: The keypad does not indicate on receipt of the kissoff signal.

Show Handshake
No
Yes/No
YES: The keypad indicates when the dialer receives the handshake
signal from the monitoring station’s receiver.
NO: No indication for establishing communication with the MS’s
receiver

Audible Kissoff
No
Yes/No
YES: There is an audible sound emitted from the keypad when the
dialer receives the kissoff signal from the monitoring station’s
receiver.
NO: There is no audible sound on receipt of the kissoff signal.

SIA Text
No
Yes/No
Yes: SIA format report to monitoring station will support text
transmission over the voice channel.
Note
The monitoring station receiver should support the SIA Text protocol
No: SIA format will not support text

Table of Contents