Quick Keys Parameter Default Range

Strobe
Use this menu to define parameters relating to the sounder strobe

Strobe Control
Follow Bell
Defines the strobe operation mode.
ALWAYS OFF - The strobe is deactivated.
FOLLOW BELL — The strobe is activated when the siren bell is
triggered.
FOLLOW ALARM — The strobe is activated when an alarm occurs in
the selected siren’s partitions.

Strobe Blink
40
Defines the number of times that the strobe will blink in a minute.
20 [Times/Min]
30 [Times/Min]
40 [Times/Min]
50 [Times/Min]
60 [Times/Min]

Arm Squawk/Flash
01 01-20 (seconds)
The time that the strobe will blink when the system is armed.
Note
If the siren’s squawk strobe is defined as NO (see the add/delete module,
 page 195) this parameter will be ignored.

Siren LED
Follow Arm
Defines the operation mode of the Status LED2.
ALWAYS ON — The status LED2 is always on.
ALWAYS OFF — The status LED2 is deactivated.
FOLLOW ARM — The status LED2 is activated when any of the siren
selected partition is armed (Away or Stay mode).
FOLLOW ALARM - The status LED 2 is activated after any alarm
condition.
ALTERNATE (only for Lumin8) — The status LEDs will constantly
alternate
.
FLASH (only for Lumin8) — The status LEDs will constantly flash.