Quick Keys Parameter Default Range
Battery Load Test
Every 24 Hours
Enables to set the time period that the ProSYS Plus will automatically
generate a Load test on
NEVER: The system will not set a battery load test
EVERY 24 HOURS
Proximity Level Response
3
0—9 (seconds)
(Only for ProSound)
Defines the time (seconds) for which a proximity violation must exist
before the siren triggers an anti-approach alarm. The option 0 indicates
that the proximity is deactivated.
Volume
9
0—9 (seconds)
Sets the bus siren's internal speaker Alarm volume. The volume ranges
between 0 (silent) to 9 (max volume). After setting/changing the volume,
sound will be emitted by the internal speaker to enable evaluation of the
selected volume level.
Lamp
Use this menu to define parameters of the sounder external Lamp.
Type
Defines the way the external lamp will be operated.
ALWAYS ON–The lamp is always on.
ALWAYS OFF–The lamp is always off.
SCHEDULER– The lamp operates according to the time defined under
the Sounder Lamp menu (Quick Key:
).
Brightness
05
(01
—10%)
Used to set the brightness level of the external lamp.
Power Source
SAB
SAB/SCB
(Only for Lumin8)
Used to define the SAB or SCB power source mode of the LuMIN8:
SAB—Power supply for the sounder will be drawn from the control
panel.
SCB—Power supply for the sounder will be drawn from the sounder’s
rechargeable battery.