2017 Page 204 5IN2413 B
Quick Keys Parameter Default Range

Siren Current
Standard Standard/Low
(Only for Lumin8)
Set the sounder current mode.
LOW – The sounder output will be reduced to 106dB 150mA.
STANDARD - The sounder output will be 112dB 350mA (assuming
single piezo head).
 
Alarm Sound
(Only for Lumin8)
Set the type of the alarm sound. Specify which of four alarm sounds is
associated with this siren.
 
Serial Number
(Only for Lumin8)
The identifying 11-digit number of the sounder (display only)
 
Supervision
(Only for Lumin8)
Determines if this zone will be supervised by the system expander
according to the time defined under the timer RX Supervision (see
RX Supervise, page 79).
Device Sounder Parameter 2-Way WL Sounders
Quick Keys Parameter Default Range
 
Label
You can define a label(name/description) for a sounder
 
Strobe
Use this menu to define parameters relating to the sounder strobe

Control
Follow Bell
Defines the strobe operation mode:
ALWAYS OFF - The strobe is deactivated.
FOLLOW BELL — The strobe is activated when the siren
bell is triggered.
FOLLOW ALARM — The strobe is activated when an alarm
occurs in the selected siren’s partitions.