EasyManua.ls Logo

Risco ProSYS Plus - Page 224

Risco ProSYS Plus
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
/
2017 Page 224 5IN2413 B
Event Message Description
GSM:IP Trouble IP address is incorrect
GSM:Mdl comm.OK Communication between the GSM/GPRS Module and the ProSYS
Plus is OK
GSM: Module comm. Internal GSM/GPRS bus module trouble
GSM:MS OK GPRS communication to the MS is OK
GSM:MS trouble GPRS communication failure to the MS
GSM:NET avail. GSM network is not available
GSM:NET avai.OK GSM Network is available
GSM:NET qual.OK GSM Network quality is acceptable
GSM:NET quality The GSM RSSI level is low
GSM:PIN cod.err PIN code entered is incorrect
GSM:PIN code OK PIN code is correct
GSM:PUK Cod err PUK code required
GSM:PUK Code OK PUK Code entered is correct
GSM:SIM OK SIM Card in place
GSM:SIM trouble SIM card missing or not properly sited
H.Temp rst Z=xx High temperature alert restored from zone XX defined as a
temperature detector
High Temp. Z=xx High temperature alert from zone XX defined as a temperature
detector
HOM:P=y C=zz Partition Y is armed in Stay mode by user ZZ
HOME:P=y KF=zz Partition Y is home armed using keyfob ZZ
HU.ReinstateP=y Hold-Up Reinstatement in partition y
IPC:DHCP error Failed to acquire an IP address from the DHCP server
IPC:DHCP OK Succeeded to acquire an IP address from the DHCP server
IPC: downld err IP Card generated a download error
IPC: download OK IP Card download was OK
IPC: evnt log ER IP Card generated an event log error
IPC: evnt log OK IP Card event log generated no error
IPC: hardware OK IP Card hardware is OK
IPC: hardware error IP Card generated a hardware error
IPC: mail error IP Card generated a mail error
IPC: mail OK IP Card mail is OK
IPC:MS=y error IP Card Monitoring station ID=Y generated an error
IPC:MS=y OK IP Card Monitoring station ID=Y was OK
IPC: Network err Failed to connect to IP network
IPC: Network OK Successful connection to IP network

Table of Contents

Other manuals for Risco ProSYS Plus

Related product manuals