11
/
2017 Page 225 5IN2413 B
Event Message Description
IPC:NTP error Failed to acquire time data from the time server
IPC:NTP ok Succeeded to acquire time data from the time server
IPC: upgrade err The IP Card upgrade generated an error
IPC: upgrade OK The IP Card upgrade was OK
IR restore Z=xx Trouble restore in the IR channel of bus zone XX
IR trouble Z=xx Trouble in the IR channel of bus zone XXX
JAMM. WME=y Jamming in wireless module expander ID=Y
KeyBox Open Zxx Zone XX of type key box is open
KeyBox Rst Z=xx Zone XX of type key box is restored
KP=$ Lost Keypad is lost
KP=$ Lost Rs Lost keypad has been restored
KP=$ LOW BAT. Low Battery trouble for the keypad
KSW A: Z=xx P=Y Group A in partition Y is armed by keyswitch zone XX
KSW ARM:Z=xxP=Y Partition Y is armed by keyswitch zone XX
KSW B: Z=xx P=Y Group B in partition Y is armed by keyswitch zone XX
KSW C: Z=xx P=Y Group C in partition Y is armed by keyswitch zone XX
KSW D: Z=xx P=Y Group D in partition Y is armed by keyswitch zone XX
KSW DIS:Z=xxP=Y Partition Y is disarmed by keyswitch zone XX
LB rstr KF=yy Low battery trouble restore from wireless remote control YY
L.Temp rst Z=xx Low temperature alert restored from zone XX defined as a
temperature detector
LB RSTR Z=xx Low battery restore from wireless zone XX
Lost Z=xx Wireless zone lost, zone no. XX
Low Bat KF=xx Low battery trouble from wireless remote control ID=XX
Low Bat PS=y Low battery trouble from power supply ID=Y
Low Bat RS Z=xx Low battery trouble restored from wireless zone no. XX
Low Bat Siren=y Low battery trouble from siren ID=Y
Low bat Z=xx Low battery trouble from wireless zone no. XX
Low Temp. Z=xx Low temperature alert from zone XX defined as a temperature
detector
LRT:ACCOUNT ERR The long range transmitter account generates an error
LRT:ACCOUNT OK The long range transmitter account is OK
LRT:HARDWARE OK The long range transmitter hardware is OK
LRT:HARDWRE ERR The long range transmitter hardware generates an error
LRT:LOW BAT The long range transmitter is experiencing low battery trouble.
LRT:LOW BAT OK The long range transmitter low battery in not troubled
LRT:NO BAT The long range transmitter is experiencing no battery