System Controls Device
Quick keys Parameter Default Range

Device
This section refers to controls that apply to bus devices

Anti Mask = Tamper
No Yes/No
Used to determine the operation of anti-masking detection in a bus zone.
YES: Anti mask violation will activate tamper alarm.
NO: Anti mask violation will be regarded as trouble event.

Proximity Anti Mask
=Tamper
No Yes/No
Used to determine the operation of the proximity anti masking detection
indicated by the microwave channel in the WatchOUT DT detector.
YES: Proximity anti mask detection will activate the tamper alarm.
NO: Proximity anti mask detection will be regarded as a fault event.
Notes
The Proximity Anti Mask operates for approximately 2.2 seconds when
the detector is approached in close proximity.
Ensure that Proximity Anti Mask has been enabled when configuring the
WatchOUT DT bus zone parameters.

Audible Proximity
Tamper
No Yes/No
This parameter relates to the bus siren.
YES: A proximity anti approach violation will activate the siren.
NO: A proximity anti approach violation will not activate the siren and will
be regarded as trouble by the system.

Siren Auxiliary =
Tamper
No Yes/No
This parameter relates to the bus siren.
YES: A siren auxiliary trouble will be regarded as tamper alarm by the
system.
NO: A siren auxiliary trouble will be regarded as trouble by the system.

RF Wake-Up
No Yes/No
Toggle between Y (yes) and N (no) to define whether the system can wake
up the 2-way wireless Slim keypad during exit/entry times, or when failing
to arm the system.
YES: The system wakes up the keypad.
NO: The system cannot wake up a 2-way keypad (this saves battery life).