11
2017 Page 95 5IN2413 B
Quick keys Parameter Default Range
Key Switch Lock
No Yes/No
YES: Only a latched key switch zone can arm or disarm the system.
Note
When the system has more than 1 zone defined as latch key switch the arm /
disarm operation will occur only after all these zones are armed or disarmed
NO: Any means can be used to arm or disarm the system (keypad, remote
phone operation, etc.).
Entry Disarm
No Yes/No
Determines if the system’s disarming depends on the entry time.
YES: Only a remote control can disarm the system during the entry time.
Note
System can't be disarmed with a remote control while the system is armed.
NO: System can be disarmed during any time using any disarming device.
Proximity Disarm
No Yes/No
Determines if the system can be disarmed using a Proximity tag.
YES: The system can be disarmed using a Proximity tag.
NO: The system cannot be disarmed using a Proximity tag.
System Controls CP-01
Quick keys Parameter Default Range
CP-01
This section refers to controls that apply to comply with SIA CP 01.
Exit Restart
No Yes/No
This parameter is used to define if an exit time shall restart one additional
time while an entry/exit zone is tripped twice during exit time.
YES: Exit time will restart for one time only when an entry/exit zone is
tripped during exit time.
NO: Exit time will not be affected if an entry/exit zone is tripped during
exit time.
Auto Stay
No Yes/No
This parameter is used to define the system’s arming mode when using a
keypad and no exit/entry zone is tripped during exit mode.
YES: If no exit/entry zone is tripped during exit time the system will be
armed in partial (Stay) arming mode.
NO: If no exit/entry zone is tripped during exit time the system will be
armed in full (Away) arming mode.