EasyManua.ls Logo

Rotax 914 F - 4) Application of the Communication Program

Rotax 914 F
274 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Modification no.
- 3 -
Page
198
Date
1999 01 01
Main
914 F
01479
c) Procedure for installation of the communication program on the PC
Make sure of, which TCU and thus which program is the applicable one.
For TCU 966.470 use prog43 and for TCU 966.741 use prog46.
Switch on the PC and wait for message C:\>.
NOTE: If this message should not appear (e.g. immediate start of a
Windows-version) change over to MS-DOS level.
To establish the directory designated as 914/progxx enter the command
MD 914\progxx [Enter]
Insert program diskette into the drive "A" and enter the command
C:\>XCOPY A:*.* C:\
914\progxx\ /s [Enter]
(enter only bold face printed command).
NOTE: With this command the directory "914" with all its sub
directories will be established.
Remove diskette from drive and store safety.
ATTENTION: Perform installation of the program every time with the
original diskette.
13.6.1.4) Application of the communication program
a) Start of the program:
establish connections PC
Dongle
TCU
switch on TCU
WARNING: Ensure engine ignition "OFF" and secured against uninten-
tional "ON".
switch on PC (if not active already)
start of the program direct from MS-DOS by call.
To start the program enter with command line
C:\914\prog43\>tlr43a [Enter]
or C:\914\prog46\>tlr46a [Enter]
NOTE: If only the message C:\> appears start the program with the
same command line but in bold face print
C:\>914\prog43\tlr43a [Enter]
C:\>914\prog46\tlr46a [Enter]

Table of Contents

Other manuals for Rotax 914 F

Related product manuals