Reference Modification no.
- 0 -
Page
204
Date
1997 02 01
Main
914 F
01479
➪ Data display
See Pic. 166/167/168/169 and 170.
HISTORY_PUFFER: Is a sub program for reading, display and printing
of data stored in the TCU. Pic. 168 shows that 8 control
parameters are displayed.
The display takes place in 6 minute intervals whereby the
highest value of each period will be stored.
READ_DATA: Reads data such as serial number, time of operation and the
latest transmitted engine data from the storage in the TCU.
At reaching 100 % the reading is complete.
â—† NOTE: If this command should be carried out during establishing of
a LOG file the error message "SERIAL ACCESS DENIED"
will appear. In this case repeat the reading procedure.