Remote Base Interface
21-31
Enter RBI-1 User Function Output Group
Control a group of RBI-1 User Function Outputs.
Enter a decimal number to control a group of outputs.
The largest decimal number is determined by the number of outputs
selected by the Select Number Of User Function Outputs command
Programmer’s Note: UF-8 is the Most Significant Bit (MSB); UF-1 is the
Least Significant Bit (LSB).
Command Form:
Command Form
Select User Function Output Group (RBPW) 10 (decimal number) *
decimal number =
(See table on page 26.)
Acknowledgment: Sends OK
Errors:
Error Meaning
OFF remote base is disabled
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: After a 7K cold reset, the outputs are off. After a power
failure, the outputs will be set to the state they were in before the power failure.
Example:
To output a value of 30 to the group of outputs, enter the following:
(RBPW) 10 30 *