7K Chapter 5
5-4
Assign Control Operator Privilege Level
Limits access of control operators to the repeater functions by
assigning privilege levels to control commands.
Enter the root number of the command for which a privilege level change is
desired, then enter a 0 or 1 for the privilege level.
0 = control command may be used by either the master or the control
operator password.
1 = control command may be used only by the master password.
Command Form:
Command Form Data Digit
Assign Control Operator Privilege Level (PW) 94 (command
root number) x*
0 = used by either
password
1 = used by only
master password
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: All commands may be used by either password.
Example:
Assume the control operators have full priviledges, the default condition. To
prevent control operators from changing either the master password or the
control operator password, enter this:
(PW) 94 92 1 *
(PW) 94 93 1 *
Root 92 is the Assign Control Operator Password command on page 5-2.
Root 93 is the Assign Master Password command on page 5-3.
Note: If you want to prevent a control operator from accessing more than one
root code in a row, use the Assign Control Operator Privilege Level to a Range
of Commands command (see page 5-5.)