EasyManua.ls Logo

S-COM 7K - Assign Control Operator Privilege Level to a Range of Commands

Default Icon
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Security
5-5
Assign Control Operator Privilege Level to a
Range of Commands
Changes the Control Operator Privilege on a range of
commands.
Enter the first and last root number of the command for which a privilege
level change is desired, then enter a 0 or 1 for the privilege level.
0 = control command may be used by either the master or the control
operator password.
1 = control command may be used only by the master password.
Command Form:
Command Form Data Digit
Assign Control Operator Privilege Level to a
Range of Commands
(PW) 94 (first root
number) (last root
number) x*
0 = used by either
password
1 = used by only
master password
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: All commands may be used by either password.
Example:
Assume that you want to reset all privilege level entries for use by both
passwords, enter the following:
(PW) 94 00 99 0 *
Assume that you want to prevent control operators from changing passwords
or a privilege level enter the following:
(PW) 94 92 94 1 *
Note: If you want to prevent a control operator from accessing a single root
code use the Assign Control Operator Privilege Level command (see page
5-4.)