RTC
®
5 PC Interface Board
Rev. 1.9 e
18 Revision History
618
innovators for industry
265 get_free_variable command Added.
284 get_sync_status command Added.
291 get_value command Added (with version DLL 531, OUT 532):
Signal
= 25…42
312 laser_on_pulses_list command Changed (as of version DLL 530, OUT 531, RBF 522):
changed functionality for 2
31
Period
(2
32
–1)
388 read_mcbsp command Added (with version DLL 531, OUT 532):
No
= 3 and
set_mcbsp_in input
412 set_control_mode command,
set_control_mode_list command
Added: bit#1 (as of version DLL 528, OUT 530)
433 set_free_variable command,
set_free_variable_list command
Added.
436 set_jump_mode command Changed (as of version DLL 530, OUT 531, RBF 522):
changed error code for return values >1 (byte#1 and
byte#2)
451 set_mcbsp_freq command Added.
452 set_mcbsp_in command,
set_mcbsp_in_list command
Added.
455 set_mcbsp_out command Added (with version DLL 531, OUT 532):
Signal1, Signal2
= 25…42
456 set_mcbsp_out_ptr command Added.
470 set_pulse_picking command,
set_pulse_picking_list command
Added.
478 set_sky_writing_limit command,
set_sky_writing_limit_list
command
Added (as of version DLL 531, OUT 532).
479 set_sky_writing_mode command,
set_sky_writing_mode_list
command
Added (as of version DLL 531, OUT 532): mode 3
493 set_trigger command Added (with version DLL 531, OUT 532):
Signal1, Signal2
= 25…42
598 chapter 17 "Appendix C: The
RTC
®
5 PCIe/104 Board"
Added.