5-107
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Power–On and Power–Up
5.1 Preparing for commissioning
5.1.1 Checklist
The following checklist will help you to commissioning the supplied components
without undue problems and ensure high availability on your product:
S When handling the components, all ESD measures are observed.
S All screws are tightened with their prescribed torque.
S All connectors are plugged correctly and locked/screwed.
S All components are grounded and connected to shields.
S The load capacity of the central power supply is taken into account.
Additional points should be observed depending on the drive system used. For
detailed information, please refer to:
S SINAMICS S120
Commissioning Manual
Section: Prerequisites for commissioning
S SIMODRIVE 611 universal
/FBU/ Description of Functions SIMODRIVE 611 universal
Section: General commissioning information
All components are dimensioned for defined mechanical, climatic and electrical
environmental conditions. No limit value may be exceeded, neither during oper-
ation, nor during transportation.
In particular, the following must be observed:
S Power supply conditions
S Pollution burden
S Function–impairing gases
S Ambient environmental conditions
S Storage/transport
S Shock stressing
S Vibration stressing
S Ambient temperature
SINUMERIK
840Di sl
Drives
Limit values
5