11.6.4 Connection via Ethernet
Parameterization of handwheels connected via Ethernet modules, e.g. machine
control table ”MCP 483C IE”, is done with the following NCK machine data:
S MD11350 $MN_HANDWHEEL_SEGMENT[< Handwheel_No. – 1>] = 7
When connected via Ethernet module, the hardware segment has always to
be entered as 7 (Ethernet).
Note
The following machine data are not evaluated with connection via Ethernet:
S MD11351 $MN_HANDWHEEL_MODULE (handwheel module)
S MD11352 $MN_HANDWHEEL_INPUT (handwheel input)
Handwheel assignment of handwheels connected via Ethernet modules cannot
be changed.
Handwheel
number in NCK
Machine data set
(Index)
Terminal
1 0 1st MCP, 1st handwheel connection
(X60)
2 1 1st MCP, 2nd handwheel connection
(X61)
3 2 2nd MCP, 1st handwheel connection
(X60)
The fourth handwheel in NCK has not been used (gap in machine data).
Parameterization of 2 handwheels, connected via a machine control table ”MCP
483C IE”.
Table 11-53 Handwheel assignment
Machine data Value Description
1st handwheel in NCK
MD11350 $MN_HANDWHEEL_SEGMENT[0] 7 Hardware segment: Ethernet
2nd handwheel in NCK
MD11350 $MN_HANDWHEEL_SEGMENT[1] 7 Hardware segment: Ethernet