01/2007
8.7 DP slave: MCP 483
8-211
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
In the example (Fig. 8-18) version number: V 01.02.00 is displayed.
1st digit
left LED block
2nd digit
center LED block
3rd digit
right LED block
Enable software version display
(press both keys
simultaneously)
Fig. 8-18 MCP software version display
The PROFIBUS address and connection type are set with switch S3 on the rear
of the MCP:
Table 8-4 Switch S3: PROFIBUS address (1 – 7)
10
9 8 7 6 5 4 3 2 1 Meaning/value
on on – – – – – – – – Connection type: PROFIBUS
– – off – – – – – – – Reserved
PROFIBUS address
– – – off off off off off off off 0
– – – off off off off off off on 1
– – – on off off off off on off 2
– – – off off off off off on on 3
– – – : : : : : : : :
– – – on on on on on on off 126
– – – on on on on on on on 127
Switch settings 10 – 8 must be set according to the data in the table.
Notice
In the state as delivered, the connection type is: MPI (10 – 9: off, off).
8.7.3 Functions of the machine control panel
The machine control panel offers the following functions:
S Default
S Hand wheel
S Additional I/Os
Switch S3
8 PROFIBUS DP Communication