2.7 TCU (Thin Client Unit)
X203/X204: 2 USB–A ports
X202: Ethernet interface
X201: Compact Flash interface
X207/X208: Interfaces for
connection to the operator panel
front (covered)
Ethernet cable
Fig. 2-15 TCU with Ethernet cable plugged in
Designation
Order No. (MLFB)
TCU (Thin Client Unit) 6FC5312–0DA00–0AA1
A TCU permits the distributed connection of SINUMERIK OP/TP operator panel
fronts and the SINUMERIK PCU. The features include the following:
S Communication with the PCU is performed via Industrial Ethernet
(10/100 Mbaud) in a separate sub–network with DHCP server (on the PCU).
S Permits large distances between the PCU and operator panel front (maxi-
mum possible distance between two network nodes/access points: approx.
100 m).
S Graphics resolutions: 640x480 to 1024x768 pixels; depth of color: 16 bits
S Interfaces:
– 1 x Ethernet 10/100 Mbaud
– 1 x Compact Flash
– 2 x USB 1.1 for connection of mouse and keyboard
– Interfaces for operator panel front:
LVDS interface for SINUMERIK OP,
USB interface for SINUMERIK OP (internal)
Order number
Features
2 Hardware Descri
tions