01/2007
6.3 Creating a SIMATIC S7 project
6-144
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
6.3.6 Parameterizing the PROFIBUS interface (X102) (optional)
When you have completed the ”Properties – PROFIBUS DP Interface” dialog
box (see previous Section 6.3.5, Page 6-143) the 840Di sl Rack is displayed in
the Station window.
HW Config – [SINUMERIK (configuration) –– SIN840Di sl]
Default
840Di sl
Profile:
(0) 840Di sl
Slot
Module...                   Order number                   Fi...    M..   E...    A...   K...
PROFIBUS DP
PROFIBUS PA
SIMATIC 300
C7
CP–300
CPU –300
FM –300
IM –300
M7 EXTENSION
Gateway
PS–300
RACK–300
SM –300
SINUMERIK
840Di sl
840Disl PLC317–2DP_2AJ10
SINUMERIK 840Di sl
Station  Edit  Insert  Target System  View   Tools  Window  Help
(0) 840Di sl
PROFIBUS(1): DP master system(1)
Search:
2 PLC 317–2DP 2AJ10
X1 MPI/DP
X2 DP
4 NCK 840D sl
5 CP 840D sl
2 PLC 317–2DP 2AJ10 6FC5 317–2AJ10–0AB0 V2.1
X1 MPI/DP
X2 DP
4 NCK 840D sl
5 CP 840D sl
8191
8190
256*
272.. 272..V0.0
PROFINET IO
Fig. 6-6 HW Config: SINUMERIK 840Di sl Rack
To parameterize the PROFIBUS interface (X102) as for slot X1, set the following
parameters:
S Interface type
S Transmission rate
Double–click module: MPI/DP, slot X1 in the 840Di sl Rack, to open the MPI/DP
Properties dialog box.
Dialog box: MPI/DP Properties
Tab: General
Name: <Designation of 2nd DP interface>
Group: Interface
Type: PROFIBUS
Button: ”Properties...”
Dialog box: Properties – PROFIBUS MPI/DP Interface 
Tab: Parameter
Address: <Address>
Button: ”New...”
Dialog box
6 PLC Commissionin