01/2007
2.11 I/O module PP72/48
2-90
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
2.11.6 Technical data
Technical data of I/O module PP72/48
Safety
Degree of protection IP 00
Safety class Safety class I, in accordance with VDE 0106 P1: 1982
(IEC 536);
Protection against ingress of foreign bodies and water in
accordance with IEC 529
Approvals UL/CSA, CE
Power consumption
At nominal load 11W
Mechanical data
Dimensions WxHxD [mm] 194 x 325 x 35
Weight Approx. 0.3 kg
without mounting plate
Approx. 1.2 kg
with mounting plate
Ambient environmental conditions
Heat dissipation Open circuit ventilation
Operation Storage/transport
Temperature limits
0 ... 50°C –20 ... 55°C/–40 ... 70 °C
Limits for relative humidity
5 ... 95 %
without condensation
5 ... 95 %
without condensation
Condensation Not permissible
Atmospheric pressure 700 ... 1060 hPa 700 ... 1060 hPa
Transportation altitude – –1000 ... 3000 m
Shock stress during transportation
Free fall in transport packa-
ging
1000 mm
2 Hardware Descri
tions