5.4 Service Desktop
5-120
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
5.4.5 Starting OEM programs
OEM programs can be executed before starting the SINUMERIK system soft-
ware. These programs or their respective links must be stored in the following
directories:
S C:\RunOEM\SeqOnce
Programs stored here are started once
and sequentially.
S C:\RunOEM\Seq
Programs stored here are started on every power–up
and sequentially.
Note
Sequential
: The subsequent program will only be started when the previous
program has been ended.
S C:\RunOEM\ParOnce
Programs stored here are started once
. They run in parallel with the HMI
system software.
S C:\RunOEM\Par
Programs stored here are initiated at every boot
. They run in parallel with
the HMI system software.
Directories and programs are processed in the following order:
S Directories
1. C:\RunOEM\SeqOnce
2. C:\RunOEM\Seq
3. C:\RunOEM\ParOnce
4. C:\RunOEM\Par
S Programs
The programs within a subdirectory are started according to the chronologi-
cal order in which they were placed in the subdirectory.
In addition to executable programs, you can also place data files in the subdi-
rectories. They will be opened in the application with which their file type is as-
sociated.
Example:
S File type: ”.txt” –> Notepad
S File type: ”.htm”–> Internet Explorer