01/2007
6.3 Creating a SIMATIC S7 project
6-145
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Dialog box: Properties – New PROFIBUS Subnet
Tab: Network settings
Transmission rate: <Trans.rate>
Profile: DP
OK
Tab: Mode
Radio button: <Mode> 
OK
OK
6.3.7 Parameterizing the MPI interface (X102) (optional)
When you have completed the ”Properties – PROFIBUS DP Interface” dialog
box (see previous Section 6.3.5, Page 6-143) the 840Di sl Rack is displayed in
the Station window.
To parameterize the MPI interface you will have to make the following parame-
ter settings:
S Interface type
S Transmission rate
Double–click module: MPI/DP, slot X1 in the 840Di sl Rack, to open the MPI/DP
Properties dialog box.
Dialog box: MPI/DP Properties
Tab: General
Group box: Interface
Type: MPI
Button: ”Properties...”
Dialog box: Properties – MPI Interface MPI/DP
Tab: Parameter
Address: 2 (see note)
Subnet: MPI(1) 187.5 kbaud
OK
OK
Notice
With SINUMERIK 840Di sl, the MPI address of the PLC must always be set
to 2.
6.3.8 Parameterization of the communications processor (CP 840D sl)
(Ethernet)
For the parameterization of the integrated communications processor:
”CP 840D sl”, the following parameters have to be set:
S IP address of the PCU
S Subnet mask of the PCU
Dialog box
6 PLC Commissionin