6.3 Creating a SIMATIC S7 project
6-146
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
S PCU gateway type
S Subnet
Note
Determining the IP address and subnet mask of the PCU:
On the PCU: Windows XP taskbar: Start > Run, Command: ipconfig
Double–click module: CP 840D sl, Slot 5 in the 840Di sl Rack, Properties dialog box:
Dialog box: Properties CP 840D sl
Tab: General
Group box: Interface
Button: ”Properties...”
Dialog box: Properties – Ethernet interface CP 840D sl
Tab: Parameter
IP address: <IP address of the PCU> (1)
Subnet mask: <Subnet mask of the PCU> (2)
Group: Gateway
Option: No router
(3)
Group: Subnet
Button: ”New...” (4)
Dialog box: Properties – New subnet Ind. Ethernet
Name: <Name>
OK
OK
OK
Properties – Ethernet interface CP 840D sl (R0/S5)
General Parameter
IP address:
No router
Subnet mask:
Gateway
Address:
Ethernet (1)
––– not networked
–––
Use router
New...
Properties...
Delete
Subnet:
10.113.22.24
255.255.255.0
10.113.22.24
4
1
3
2
Fig. 6-7 Parameterize the properties of the CP 840D sl (excerpt)
Notice
The IP address and subnet mask in the figure above are only sample values!
Dialog box
6 PLC Commissionin
g