EasyManua.ls Logo

Siemens Sinumerik 840DiE sl - Axis and Spindle Test Run

Siemens Sinumerik 840DiE sl
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13-421
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Axis and Spindle Test Run
13.1 Prerequisites
Enabling signals must be set to allow an axis to be traversed directly from the
control:
S Drive: Parameters and terminals
S NCK: Interface signals
13.1.1 Drives: SINAMICS S120
Infeed
Parameter/Terminal Significance
p0840 ON/OFF1
p0844 1st OFF2
p0845 2nd OFF2
p0852 Enable operation
X21.3 (+24 V) and X21.4 (ground) EP terminals enable (pulse enable)
Drive
Parameter/Terminal Significance
p0840 ON/OFF1
p0844 1st OFF2
p0845 2nd OFF2
p0848 1st OFF3
p0849 2nd OFF3
p0852 Enable operation
X21.3 (+24 V) and X21.4 (ground) EP terminals enable (pulse enable)
p0864 Infeed enable
p1140 Ramp–function generator enable
p1141 Ramp–function generator Start
p1142 Setpoint enable
SINAMICS S120 Commissioning Manual
/GH2/ Booksize Power Modules Manual
13.1.2 Drives: SIMODRIVE
Applies to the following SIMODRIVE drives:
S SIMODRIVE 611 universal/universal E
S SIMODRIVE POSMO SI, CD/CA
References
13

Table of Contents

Related product manuals