Axis and Spindle Test Run
13.1 Prerequisites
Enabling signals must be set to allow an axis to be traversed directly from the
control:
S Drive: Parameters and terminals
S NCK: Interface signals
13.1.1 Drives: SINAMICS S120
Infeed
Parameter/Terminal Significance
p0840 ON/OFF1
p0844 1st OFF2
p0845 2nd OFF2
p0852 Enable operation
X21.3 (+24 V) and X21.4 (ground) EP terminals enable (pulse enable)
Drive
Parameter/Terminal Significance
p0840 ON/OFF1
p0844 1st OFF2
p0845 2nd OFF2
p0848 1st OFF3
p0849 2nd OFF3
p0852 Enable operation
X21.3 (+24 V) and X21.4 (ground) EP terminals enable (pulse enable)
p0864 Infeed enable
p1140 Ramp–function generator enable
p1141 Ramp–function generator Start
p1142 Setpoint enable
SINAMICS S120 Commissioning Manual
/GH2/ Booksize Power Modules Manual
13.1.2 Drives: SIMODRIVE
Applies to the following SIMODRIVE drives:
S SIMODRIVE 611 universal/universal E
S SIMODRIVE POSMO SI, CD/CA
References