EasyManua.ls Logo

Siemens Sinumerik 840DiE sl - Page 398

Siemens Sinumerik 840DiE sl
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01/2007
11.7 Digital and analog I/O devices
11-398
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Table 11-56 Digital and analog I/Os: Interface signals
DB
number
Bit, byte Name Refer-
ence
General Signals from PLC to NCK
10 0, 122, 124, 126, 128 Disable digital NCK inputs
10 1, 123, 125, 127, 129 Setting on PLC of digital NCK inputs
10 4, 130, 134, 138, 142 Disable digital NCK outputs
10 5, 131, 135, 139, 143 Overwrite mask for digital NCK outputs
10 6, 132, 136, 140, 144 Setting value from PLC for the digital NCK outputs
10 7, 133, 137, 141, 145 Setting mask for digital NCK outputs
10 146 Disable analog NCK inputs
10 147 Setting mask for analog NCK inputs
10 148–163 Setting value from PLC for the analog NCK inputs
10 166 Overwrite mask for analog NCK outputs
10 167 Setting mask for analog NCK outputs
10 168 Disable analog NCK outputs
10 170–185 Setting value from PLC for the analog NCK outputs
Signals from NCK to PLC
10 60, 186–189 Actual value for digital NCK inputs
10 64, 190–193 Setpoint for digital NCK outputs
10 194–209 Actual value for analog NCK inputs
10 210–225 Setpoint for analog NCK outputs
Interface signals