Vista 5 M3 Digital Mixing System
AutoTouchPlus 5-89
Document generated: 28.08.13
SW V4.9
5.13 Other Automated Functions
There are several ancillary functions that may be automated. These functions
are described below.
5.13.1 Bus Assignments
Bus Assignments may be automated. Both ‘assignment’ and ‘de-assign ment’
operations may be stored as Static objects or recorded as Dynamic objects.
Bus Assignments follow the rules of a Press and Release or Press and Hold
switch operation. Refer to chapter 5.11. All Mix Pass Write To: and Extend
Back To: conditions apply, except ‘Write To : Punch Out.’
As with any control, changes to Bus Assignments may Auditioned.
Record a Bus Assignment To automate a Bus Assignment, use the following procedure:
1.
Select the desired global Control Mode. Write will overwrite previous
changes, both location and connection type.
2.
Select TOUCH – Record.
3.
Select the desired Write To: function.
4.
Activate BUS ASN in the Touch Screen Area below the Vistonics™ sec-
tion.
5.
Press the desired bus number to make the assignment.
6. Press and Release or Press and Hold switch rules will apply depending
on how the switch is operated.
7.
When timecode is stopped, a new Mix Pass will be generated.
Note Like any other object within AutoTouchPlus, all Bus Assignments are Static
objects until a change state is recorded in the system. Therefore, Bus Assign-
ments may be updated in the same manner as any other Static control.