EasyManua.ls Logo

Studer Vista 5 M3 - IP Addresses

Studer Vista 5 M3
564 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vista 5 M3 Digital Mixing System
RELINK 8-17
Document generated: 28.08.13
SW V4.9
8.5.8 IP Addresses
The IP addresses of the SCore Live bridge cards should not be changed. They
are always set to 192.168.1.60 for the primary network port, and to 192.168.2.60
for the secondary network port.
Note: In case of a network design where more than one Vista console communicates
with its SCore through one and the same Ethernet switch, the IP addresses
may be changed as with the OnAir console range. But then the Vista’s
D950System.ini files need to be adapted accordingly.
8.5.9 Audio Sync for all Systems
All systems being part of the network that can exchange audio via tie lines
must be properly synchronized. The best option to do this is having a Studer
D21 MasterSync unit feeding word clock in a star configuration to all the
systems involved.
If a single system cannot be synchronized, either AES/EBU cards with SFCs
or analog cards have to be used for tie lines.