SCore Live
4 SCore Live
Document generated: 20.09.13
Ventilation Implementation A power dissipation estimation, considering the number of cards and their
configuration within the frame, is strongly recommended. The following
tables give some guidelines.
Card No. Card Name/Description
Dissipation
(approx.)
Backplane with power supply 10 W
DSP cards
A943.0326 Host card 10 W
A943.0331 Ext. Sync card 0.2 W
A943.0360 DSP Pro card 11 W
A94x.0370
B
ridge card (Redundant versions: A94x.0370.35 and up)
11 W
D21m I/O cards (for details, refer to the separate D21m I/O Operating Instructions)
A949.0427 Mic/Line in card 11 W
A949.0428 Analog insert card 2 W
A949.0421 Line In card 7 W
A949.0420 Line out card 7 W
A949.0422 AES/EBU card 3.5 W
A949.0423 AES/EBU card with input SFC 4.5 W
A949.0424 AES/EBU card with input/output SFC 5.5 W
A949.0430 MADI card 4.5 W
A949.0425 ADAT card 1.7 W
A949.0429 ADAT card, long-distance option 1.7 W
A949.0426 TDIF card 1 W
A949.0412 HD card 5 W
A949.0411 MADI HD card 5.5 W
A949.0437 Serial card 0.2 W
A949.0438 Serial Merger card 0.6 W
A949.0435 GPIO card 3 W
Setup A: Closed Setup B: Passive,
2 Air Deflector Units
Setup C: Active, 1 Fan
Unit, 1 Air Deflector Unit
Rear Rear
Air
Air
Air
Air
RearFront Front Front
Setup D: Active, 1 Fan
Unit, 2 Air Deflector Units
Air
Air
Rear Front
SCore Live SCore Live SCore Live SCore Live
Thermal
Setup
Total
Height
Max.
Dissipation
Restrictions Bottom Cooling Top Cooling
A
6 U 50 W - - -
B
8 U 100 W - Deflector Unit Deflector Unit
C
8 U 150 W
Config. N1...N4
(see below)
Fan Unit Deflector Unit
D
9 U 400 W -
Deflector Unit
+ Fan Unit
Deflector Unit
If required, the air flow direction may be changed by reversing the deflector
and fan units. However, air intake at the front and air outlet at the rear is the
recommended scheme.