Keywords
Keyword Description
100 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Response Example:
SYMMBITS 04-06-18 11:40:54
M SC050 COMPLD
"OUTA-PG1::CCDEL = 80"
;
CCDENB (CC Delay)
This keyword enables the delay for a specific port on an Output Connector card.
The keyword format is:
CCDENB=<value>
CLRPTALL (Clear Port Alarm)
This keyword provides a method for attempting to clear an output port alarm that
may have become set due to a temporary external condition. When an
externally-induced port alarm occurs, removal of the condition that caused the
alarm causes the output port alarm to self-clear. However, in a situation where the
temporary external condition causes only one Output card of a protected pair to
alarm, the alarm does not self-clear when the external condition is removed. You
can clear this type of alarm using CLRPTALL. The keyword format is:
CLRPTALL=<value>
Parameter Value Description
<value> Y Delay is enabled
N Delay is disabled
Note: If this keyword is enabled, the amount of delay is controlled by
the CC Delay Value (CCDEL).
Parameter Value Description
<value> Y Attempt to clear any port alarms on Output cards in the selected
Output card group and then value is set to N. The clearing
attempt is performed once when the value is set to Y.
N Do not attempt port alarm clear. When the CLRPTALL value is
queried, it is nearly always set to N since the TimeHub 5500
automatically sets the value to N after a port alarm clear
attempt.