097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 69
Commands
Command Description
RTRV-EQPT::CLK:SC1:::PARAMETER=INPLOS;
The command in this example displays the properties for the Input Loss Of Signal
event.
RTRV-EQPT::OUTA:SC1:::PARAMETER=HLDACT;
The command in this example displays the Output card A holdover action setting.
RTRV-EQPT::S2-OUTA:SC1:::PARAMETER=HLDACT&AIS;
The command in this example displays the holdover action setting for Output card A
of shelf 2 and displays if AIS is the normal output for Output card A.
RTRV-EQPT::CLK:SC1:::PARAMETER=SPRD-12S;
SYMMBITS 01-05-24 11:25:52
M SC1 COMPLD
"CLK::SPRD-12S = THR-0.000 & CRI-N & RPT-N & PM-M"
;
The command in this example displays the threshold value along with the CRI, RPT,
and PM settings.
Retrieve Equipment Type
This command displays basic information about the TimeHub 5500. The command
format is:
RTRV-NETYPE:::<ctag>;
Command Example:
RTRV-NETYPE:::SC1;
The command in this example displays basic information about the TimeHub 5500.
Response Format:
<sid> <date> <time>
M <ctag> COMPLD
"<company>,<model number>,<equipment type>,
<management card firmware revision>"
;
Retrieve Header
This command displays the response header information which includes the system
identification (<sid>), date, and time for the unit. It can be used to verify operation of
the communication link between the TimeHub 5500 and the computer
communication port. The command format is:
RTRV-HDR:::<ctag>;

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals