EasyManuals Logo

Symmetricom TimeHub 5500 Reference Guide

Symmetricom TimeHub 5500
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Keywords
Keyword Description
124 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
OMANSSM (Output Manual SSM)
This keyword allows the user to set the SSM quality level for the specified output
slot pair (OQLEVEL). For this keyword to be effective, the output format must be set
to Y (OUTESF=Y). The keyword format is:
OMANSSM=<value>
OQLEVEL (Output Quality Level)
This keyword specifies the SSM quality level for the specified output slot pair. This
SSM level is used when the Output Manual SSM function is enabled
(OMANSSM=Y). The keyword format is:
OQLEVEL=<value>
Parameter Value Description
<value> Y Disabled input events are not
suppressed
N Disabled input events are suppressed
Parameter Value Description
<value> Y Allow user to specify SSM quality
level
N Do not allow user to specify SSM
quality level
Parameter Value Description
<value> 1 Stratum 1 Traceable (PRS)
2 Synchronized – Traceability Unknown (STU)
3 Stratum 2 Traceable (ST2)
4 Transit Node Clock Traceable (TNC)
5 Stratum 3E Traceable (ST3E)
6 Stratum 3 Traceable (ST3)
7 SONET Minimum Clock (SMC)
8 Do not use for synchronization (DUS)

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals