Commands
Command Description
62 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Retrieve Equipment
This command displays equipment parameters and can only be used with keywords
that relate to a card, but not to a specific input or output port. The command format
is:
RTRV-EQPT[-TSG]:[<tid>]:[<aid>]:<ctag>:::PARAMETER=<keyword>;
Note: For detailed descriptions of keywords, see Chapter 3,
Keywords.
Parameter Value Variables Description
<aid> CLK Clock card. This parameter is
optional.
IMC Management card. This parameter is
optional.
Sa-OUTb a = 1 Shelf number. This parameter is not
optional.
b = A, B, C, or D Output driver card letter. This
parameter is not optional.