Commands
Command Description
82 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
The command format is:
SET-SYNCN:[<tid>]:<aid>:<ctag>::NORM;
Command Example:
SET-SYNCN::CLK1:SC1::NORM;
The command in this example forces Clock card 1 to assume its oven is fully
warmed up.
Set System Identifier
This command sets the name of the equipment sending the message. The
command format is:
SET-SID:[<tid>]::<ctag>::<sid>;
Command Example:
SET-SID:::SC1::SYMMBITS2;
The command in this example sets the system identification code to SYMMBITS2.
Parameter Value Description
<aid> CLK1 Clock card 1
CLK2 Clock card 2
Parameter Value Description
<sid> 1 to 20 alphanumeric characters Source identifier. Factory set value is
SYMMBITS.
Note: If a target identifier (<tid>) is included in a command, it is
compared against the system identifier (SID) of the TimeHub 5500
and the command is only executed if these match. If they do not
match, the command is rejected.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals