Keyword Description
120 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-EQPT::IMC:SC779:::PARAMETER=IPSUBNETX;
Response Example:
SYMMBITS 04-06-18 11:58:40
M SC779 COMPLD
"IMC::IPSUBNETX = 0.0.0.0"
;
LCLAO (Local Automatic Output)
This keyword sets the local port to report automatic messages always, never, or
only when logged into the local port. The keyword format is:
LCLAO=<value>
Command Example:
RTRV-EQPT:::SC801:::PARAMETER=LCLAO;
Response Example:
SYMMBITS 04-06-18 11:58:49
M SC801 COMPLD
"IMC::LCLAO = LOGIN"
;
LCLBAUD (Local Baud Rate)
This keyword sets the baud rate on the local port.
Parameter Value Description
<value> ALWAYS Always report automatic messages
LOGIN Only report automatic messages when
logged into the local port
NEVER Never report automatic messages
Note: The baud rate of the port in use cannot be set.