132 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-SYNC::CLK-0:SC1293:::PARAMETER=QLEVEL;
Response Example:
SYMMBITS 04-06-18 12:02:38
M SC1293 COMPLD
"CLK-0::QLEVEL = 6"
;
REVERT (Revertive Mode)
This keyword controls how an input reference is chosen in automatic and manual
mode. The keyword format is:
REVERT=<value>
Parameter Value Description
<value> 1 Stratum 1 Traceable (PRS)
2 Synchronized – Traceability Unknown (STU)
3 Stratum 2 Traceable (ST2)
4 Transit Node Clock Traceable (TNC)
5 Stratum 3E Traceable (ST3E)
6 Stratum 3 Traceable (ST3)
7 SONET Minimum Clock (SMC)
8 Stratum 4 Traceable (ST4)
9 Do not use for synchronization (DUS)
Parameter Value Description
<value> Y Highest priority qualified input is always chosen
as the active input
N Current input remains active until it is disqualified