Keywords
Keyword Description
110 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-EQPT::IMC:SC639:::PARAMETER=INACTTIME;
Response Example:
SYMMBITS 04-06-18 11:45:59
M SC639 COMPLD
"IMC::INACTTIME = 200"
;
INSRVC (In Service)
This keyword disables an Output Driver card (in case maintenance is required). The
keyword format is:
INSRVC=<value>
IPEM1 (IP Address of Primary Element Manager–Working
Memory)
This keyword sets the primary element manager IP address in working memory.
Working memory controls the actual operation of the network. The keyword format
is:
IPEM1=<a.b.c.d>
Parameter Value Description
<value> Y Disabled output
N Enabled output
Parameter Value Description
a 0 to 255 Working memory primary element
manager IP address
b 0 to 255
c 0 to 255
d 0 to 255
Note: You cannot directly modify network parameters in working
memory.