Keywords
Keyword Description
108 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-EQPT::CLK:SC566:::PARAMETER=HFQLEVL;
Response Example:
SYMMBITS 04-06-18 11:45:28
M SC566 COMPLD
"CLK::HFQLEVL = 4"
;
HFQLEVLSEC (Holdover and Freerun Quality Level
for Secondary Oscillator)
This keyword defines the quality assumed for the secondary Clock card (with the
lower quality oscillator) in a mixed Clock card pair in SSM mode.
The quality level value is only transmitted if the secondary Clock card becomes
active while it is in holdover.
The keyword format is:
HFQLEVLSEC=<value>
Command Example:
RTRV-EQPT::CLK:SC581:::PARAMETER=HFQLEVLSEC;
Parameter Value Description
<value> 1 Stratum 1 Traceable (PRS)
2 Synchronized – Traceability Unknown (STU)
3 Stratum 2 Traceable (ST2)
4 Transit Node Clock Traceable (TNC)
5 Stratum 3E Traceable (ST3E)
6 Stratum 3 Traceable (ST3)
7 SONET Minimum Clock (SMC)
8 Do not use for synchronization (DUS)

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals