EasyManuals Logo

Symmetricom TimeHub 5500 Reference Guide

Symmetricom TimeHub 5500
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 109
Keywords
Keyword Description
Response Example:
SYMMBITS 04-06-18 11:45:35
M SC581 COMPLD
"CLK::HFQLEVLSEC = 4"
;
HLDACT (Holdover Action)
This keyword controls the Output Driver card operation when the system is in
holdover. The keyword format is:
HLDACT=<value>
Command Example:
RTRV-EQPT::OUTA:SC594:::PARAMETER=HLDACT;
Response Example:
SYMMBITS 04-06-18 11:45:41
M SC594 COMPLD
"OUTA::HLDACT = CONTINUE"
;
INACTTIME (Inactivity Time-out)
This keyword specifies the length of time a connection to the event reporting port
(PORTAO) continues without the occurrence of an automatic output message. The
inactivity timer has a setting range of 0 to 10000 and each setting has a time value
of 0.1 seconds (100 ms). For example, a setting of 100 specifies that after
10 seconds without an automatic message the connection to the TimeHub 5500
PORTAO is closed. The connection is re-established when another automatic
message occurs. The keyword format is:
INACTTIME=<value>
Parameter Value Description
<value> CONTINUE Output Driver card continues to operate
AIS Output Driver card produces an AIS signal
SQUELCH Output Driver card is squelched
Parameter Value Description
<value> 0 to 10000 Timeout in units of 100 ms

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals