097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 123
Keywords
Keyword Description
Discontinuities on the input signal exceeding the Discontinuity Time (DSCTIME)
value
The Initialize Register (INIT-REG) command used to restart performance
measurements is executed with the DISQ parameter. For example:
INIT-REG::CLK-2:SC1::DISQ;
The keyword format is:
MEASDLY=<value>
Command Example:
RTRV-SYNC::CLK-1:SC839:::PARAMETER=MEASDLY;
Response Example:
SYMMBITS 04-06-18 11:59:10
M SC839 COMPLD
"CLK-1::MEASDLY = 1"
;
MONITOR (Input Event Monitoring)
This keyword allows events from disabled inputs to be suppressed.
Set this keyword to N for disabled channels that do not have an input signal
connected. If the value for the input keyword ENABLE is Y, the setting for
MONITOR has no effect.
To monitor an input signal that is not being used as a system reference, on the input
to be monitored set the input keyword ENABLE to N, set MONITOR to Y, and
connect the signal.
The keyword format is:
MONITOR=<value>
Parameter Value Description
<value> 0 to 1800 Number of minutes following
measurement restarts

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals