Commands
Command Description
34 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
CANC-BTT:SYMMBITS:CLK1:SC005;
Response Example:
SYMMBITS 04-06-15 05:01:32
M SC005 COMPLD
;
Cancel Port
This command terminates a current session on the TimeHub 5500. You can use it to
remotely cancel a session on the local port. If the port of the user is specified, the
user is logged off. The command format is:
CANC-CID-SECU:[<tid>]:<aid>:<ctag>;
Command Example:
CANC-CID-SECU::LOCAL:SC001;
Cancel User
This command logs the user off the system and ends a session. The user name is
not case sensitive, but must otherwise be entered exactly as assigned. The
command format is:
CANC-USER:[<tid>]:[<aid>]:<ctag>;
Parameter Value Description
<aid> IMC Management card
CLK1 Clock card 1
CLK2 Clock card 2
Parameter Value
<aid> REMOTE
LOCAL