097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 129
Keywords
Keyword Description
Command Example:
ED-EQPT:::SC4:::PORTCMDS=7588;
Response Example:
SYMMBITS 01-05-29 10:41:16
M SC4 DENY
"IDNV"
/* Input Data Not Valid */
/* Cannot directly set this parameter */
;
PORTCMDSX (Command/Response Reporting
Port Number–Auxiliary Memory)
This keyword sets the port number for command and response reporting in auxiliary
memory. Auxiliary memory contains a backup copy of network parameters in
working memory (working memory controls the actual operation of the network).
The keyword format is:
PORTCMDSX=<value>
Parameter Value Description
<value> 5001 to 20000 Working memory port number for
command and response reporting
Note: You cannot directly modify network parameters in working
memory.
Note: If the Automatic Output Merge function is enabled
(AOMERGE=Y) events, commands, and responses are carried on
this port.
Parameter Value Description
<value> 5001 to 20000 Auxiliary memory port number for
command and response reporting

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals