097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 125
Keywords
Keyword Description
Command Example:
RTRV-EQPT::OUTD:SC1010:::PARAMETER=OQLEVEL;
Response Example:
SYMMBITS 04-06-18 12:00:30
M SC1010 COMPLD
"OUTD::OQLEVEL = 4"
;
OUTESF (Output ESF)
This keyword sets the framing for a specific Output Connector card port group. The
keyword format is:
OUTESF=<value>
PIRANGE (Pull-In Range)
This keyword controls how far the input can be off from the absolute frequency for
the local oscillator before it is disqualified.
The keyword format is:
PIRANGE=<value>
Parameter Value Description
<value> Y ESF framing
N D4 framing
Note: This keyword applies only if the Output Connector card is a
DS1 type.
Note: Because this is over the lifetime of the oscillator, this is not a
substitute for frequency deviation.