097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 111
Keywords
Keyword Description
Command Example:
RTRV-EQPT-TSG::IMC:SC678:::PARAMETER=IPEM1;
Response Example:
SYMMBITS 04-06-18 11:46:21
M SC678 COMPLD
"IMC::IPEM1 = 0.0.0.0"
;
IPEM1X (IP Address of Primary Element Manager–Auxiliary
Memory)
This keyword sets the primary element manager IP address in auxiliary memory.
Auxiliary memory contains a backup copy of network parameters in working
memory (working memory controls the actual operation of the network). The
keyword format is:
IPEM1X=<a.b.c.d>
Command Example:
RTRV-EQPT:::SC681:::PARAMETER=IPEM1X;
Response Example:
SYMMBITS 04-06-18 11:46:22
M SC681 COMPLD
"IMC::IPEM1X = 123.123.12.123"
;
Parameter Value Description
a 0 to 255 Auxiliary memory primary element manager
IP address
b 0 to 255
c 0 to 255
d 0 to 255