Keywords
Keyword Description
130 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-EQPT::IMC:SC1131:::PARAMETER=PORTCMDSX;
Response Example:
SYMMBITS 04-06-18 12:01:28
M SC1131 COMPLD
"IMC::PORTCMDSX = 5001"
;
PRC5MHZ (PRC 5 MHz Signal)
This keyword specifies a 5 MHz or 10 MHz signal on the PRC input channel. The
keyword format is:
PRC5MHZ=<value>
PRIORITY (Input Priority)
This keyword specifies a priority for an input channel. A lower number represents a
higher priority. The channel priority is used by the selection algorithm to determine
which channel is tracked. For all channels with the same priority value, the lowest
numbered channel is considered to have top priority. For remote shelf configuration,
PRIORITY is also used to set the DS1 SSM input to use (CLK-1 or CLK-2) if both
SSM inputs are enabled and providing valid SSM. The keyword format is:
PRIORITY=<value>
Parameter Value Description
<value> Y 5 MHz signal on the PRC input channel
N 10 MHz signal on the PRC input channel
Note: This keyword should only be used with an <aid> of CLK-0.
Parameter Value Description
<value> 1 to 9 Input channel priority