112 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
IPEM2 (IP Address of Alternate Element Manager–Working
Memory)
This keyword sets the alternate element manager IP address in working memory.
The alternate element manager IP address is used for event reporting if
communication failure to the primary element manager occurs. Working memory
controls the actual operation of the network. The keyword format is:
IPEM2=<a.b.c.d>
Command Example:
RTRV-EQPT::IMC:SC692:::PARAMETER=IPEM2;
Response Example:
SYMMBITS 04-06-18 11:46:43
M SC692 COMPLD
"IMC::IPEM2 = 0.0.0.0"
;
IPEM2X (IP Address of Alternate Element Manager–Auxiliary
Memory)
This keyword sets the alternate element manager IP address in auxiliary memory.
The alternate element manager IP address is used for event reporting if
communication failure to the primary element manager occurs. Auxiliary memory
contains a backup copy of network parameters in working memory (working
memory controls the actual operation of the network). The keyword format is:
IPEM2X=<a.b.c.d>
Parameter Value Description
a 0 to 255 Working memory alternate
element manager IP address
b 0 to 255
c 0 to 255
d 0 to 255
Note: You cannot directly modify network parameters in working
memory.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals