104 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Which results in this response:
SYMMBITS 02-07-10 13:09:51
M SV01 COMPLD
;
And an automatic message showing that the condition has ended:
SYMMBITS 02-07-10 13:09:51
A 0296 REPT ALM TSG
"S2-CLK2:CL,EXCLKGONE,NSA,07-10,13-09-51:\"ENDED Expansion
CLK card missing\""
;
ECONCRD (Output Connector Card Type)
This keyword sets the requirement for the Output Connector card type. If a card
type other than the type specified is detected, or this keyword’s value is set to
EMPTY and a card exists, an event (ECCRDMM) is generated stating an Output
Connector card mismatch. The keyword format is:
ECONCRD=<value>
Command Example:
RTRV-EQPT::OUTA-PG1:SC341:::PARAMETER=ECONCRD;
Response Example:
SYMMBITS 04-06-18 11:54:40
M SC341 COMPLD
"OUTA-PG1::ECONCRD = DONT-CARE"
;
Parameter Value Description
<value> DONT-CARE No card type requirement
CC CC card type
DS1 DS1 card type
Note: Outputs are not disabled when the ECCRDMM event is
generated.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals