Commands
Command Description
76 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
RTRV-SYNC[-TSG]:[<tid>]:<aid>:<ctag>:::PARAMETER=<measurement>;
Command Examples:
RTRV-SYNC::S2-OUTA-3:SC1:::PARAMETER=SQUELCH;
The command in this example displays squelch information about Output Channel 3
on Output card A in shelf 2.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=PRIORITY;
The command in this example displays the priority of input channel 3.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=PRIORITY&ENABLE;
The command in this example displays the priority of input channel 3 and if it is
enabled.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=TDEV-1S;
The command in this example displays the properties for a 1 second TDEV
measurement on input channel 3.
Retrieve Threshold Information
This command displays the threshold of a measurement for a particular input
channel. The command format is:
RTRV-TH[-TSG]::<aid>:<ctag>::<montype>;
Parameter Value Variables Description
<aid> CLK-a a = 1 to 4 Input channel number of Clock card
Sa-OUTb-c a = 1 Shelf number
b = A, B, C, or D Output Driver card letter
c = 1 to 40 Output port number
<measurement> FFOF Fractional Frequency Offset
LMRTIE Latest Maximum Relative Time
Interval Error
MRTIE Maximum Relative Time Interval Error
SPRD Frequency Spread
TDEV Time Deviation
TIE Time Interval Error

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals