Commands
Command Description
76 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
RTRV-SYNC[-TSG]:[<tid>]:<aid>:<ctag>:::PARAMETER=<measurement>;
Command Examples:
RTRV-SYNC::S2-OUTA-3:SC1:::PARAMETER=SQUELCH;
The command in this example displays squelch information about Output Channel 3
on Output card A in shelf 2.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=PRIORITY;
The command in this example displays the priority of input channel 3.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=PRIORITY&ENABLE;
The command in this example displays the priority of input channel 3 and if it is
enabled.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=TDEV-1S;
The command in this example displays the properties for a 1 second TDEV
measurement on input channel 3.
Retrieve Threshold Information
This command displays the threshold of a measurement for a particular input
channel. The command format is:
RTRV-TH[-TSG]::<aid>:<ctag>::<montype>;
Parameter Value Variables Description
<aid> CLK-a a = 1 to 4 Input channel number of Clock card
Sa-OUTb-c a = 1 Shelf number
b = A, B, C, or D Output Driver card letter
c = 1 to 40 Output port number
<measurement> FFOF — Fractional Frequency Offset
LMRTIE Latest Maximum Relative Time
Interval Error
MRTIE Maximum Relative Time Interval Error
SPRD Frequency Spread
TDEV Time Deviation
TIE Time Interval Error