138 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
ED-EQPT::CLK:SC1419:::SPRDCHN=1&&4;
Response Example:
SYMMBITS 04-06-18 12:03:35
M SC1419 COMPLD
;
SQUELCH (Squelch Output)
This keyword specifies which output channels are to be squelched. The keyword
format is:
SQUELCH=<value>
SSMENB (Read SSM Bits)
This keyword enables the reading of the SSM bit on the specified input. If this
function is disabled (SSMENB=N), the assumed SSM value (QLEVEL) is used
instead. For an input SSM bit to be read correctly, the input format must be set to Y
(ESF=Y). This keyword has no effect on the PRC (Primary Reference Clock) input.
The keyword format is:
SSMENB=<value>
Note: SPRD is recalculated if a measurement is restarted on a
channel that is included in the SPRD calculation (for example, using
the Initialize Register [INIT-REG] command).
Parameter Value Description
<value> Y Output channel is squelched
N Output channel is not squelched
Parameter Value Description
<value> Y SSM is enabled
N SSM is disabled

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals