097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 53
Commands
Command Description
Command Examples:
INIT-LOG::CLK:SC001::EVT;
The command in this example clears the event log on both Clock cards.
INIT-LOG::CLK1:SC001::EVT;
The command in this example clears the event log on Clock card 1 only.
Initialize Register
This command clears all performance monitoring measurement data on a specific
input channel and then restarts the channel’s performance monitoring. The
command format is:
INIT-REG[-TSG]:[<tid>]:<aid>:<ctag>[::DISQ];
Command Example:
INIT-REG::CLK-1:SC001;
The command in this example clears and restarts all performance monitoring
measurements on input channel 1.
Operate Alarm Cutoff
This command deactivates (silences) the audible office alarm. The command format
is:
OPR-ACO-ALL:[<tid>]::<ctag>;
Parameter Value Description
<aid> CLK Both Clock cards
CLK1 Clock card 1
CLK2 Clock card 2
Parameter Value Variable Description
<aid> CLK-a a = 1 to 4 Number of the input channel of the Clock card
DISQ Restarts measurements on a channel and
disqualifies the channel until a good
measurement is completed

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals